Fuse the Circuit WTB2-FB130L IEC fuse holder terminal blocks have a current rating up to 30 A, and accept ¼ x 1¼ in. fuses. They have a built-in LED circuit to indicate when the fuse blows and funneled wiring entry with finger-safe IP20 terminals. Marking system allows for fast and easy circuit identification. c3controls 724/775-7926 www.c3controls.com
|
 |
Push It Modular push-in terminal (PIT) blocks reduce insertion forces compared with other spring-technology products. With a 2.5 mm2 cross section, an orange actuation button opens the spring to maximum wiring space of 14 AWG, and the devices are compatible with standardized push-in bridging, marking and testing accessories for all connection technologies. Phoenix Contact 800/322-3225 www.phoenixcon.com
|
 |
PXI I/O MODULES Four R Series I/O modules for the PXI platform are equipped with Xilinx Virtex-5 field programmable gate arrays (FPGAs). PXI-7841R, PXI-7842R, PXI-7851R and PXI-7852R modules have eight analog inputs, eight analog outputs and 96 digital I/O lines, as well as analog input rates more than 3.5 times faster than previously released R Series devices. These modules provide engineers with commercial off-the-shelf hardware that can be graphically programmed with the LabView FPGA module to perform custom onboard processing for in-line data analysis and deterministic I/O control for applications that require specialized timing and triggering. National Instruments 800/258-7022 www.ni.com
|
 |
Decentralize the I/O With IP67 protection, X67 I/O modules can be installed on the machine, and can span 100 m between modules. Users can set parameters for the digital inputs and outputs and connect to all standard fieldbuses. B&R Industrial Automation 770/772-0400 www.br-automation.com
|
 |
Motion I/O Universal I/O module for multi-axis RMC150 motion controllers has two analog inputs, six discrete I/O and two high-speed Quadrature/SSI channels. The 16-bit analog inputs can be used for pressure/force control or as position or velocity reference inputs. Quadrature/SSI channels can be configured as ½-axis quadrature or SSI reference inputs for gearing or to synchronize multiple controllers. Delta Computer Systems 360/254-8688 www.deltamotion.com
|
 |
Module Finds Trouble With KE-style enclosure-mount, four input/four output, AS-Interface I/O modules, should an output wire be disconnected, switchable lead breakage detection automatically sends the peripheral fault signal to the upper level controller. Any input pulse/noise spike less than 2 ms is automatically filtered out by input pulse suppression. Advanced diagnostic LEDs alert the user to reverse polarity, overload or short circuit conditions. Pepperl+Fuchs 330/486-0001 www.pepperl-fuchs.us
|
 |
Modbus Supporter APAX-5070 Modbus/TCP Remote I/O coupler module allows a PC, controller or HMI device that supports Modbus/TCP to add remote I/O functionality. The module has two RJ-45 ports with the same IP address, which can build daisy chains to connect remote I/O devices directly without an additional Ethernet switch. It can perform alarms without a controller, with the help of a utility to control the output module based on input conditions. Advantech Industrial Automation 800/205-7940 www.advantech.com/ea
|
 |
D-Sub Interface DSUB DIN-rail-mounted interface modules provide a reliable plug-and-play interface for any industrial control system. CE-compliant modules come with male and female D-subminiature connectors and are available as 9-, 15- and 25-pin models. Optional D-Sub cables are available. Suitable for packaging and automated assembly. Omega Engineering 203/359-1660 www.omega.com
|
 |
Digital I/O Handbook The Digital I/O Handbook covers a range of devices including optically isolated inputs, relays and sensors, and has circuit diagrams and drawings, and software code examples. Learn about real-world implementation from technical author Jon Titus and company president and CEO Tom O'Hanlan. Enter promotional code CD001. Sealevel Systems 864/843-4343 www.sealevel.com/store/ref101
|
 |
Spring and Jump HMM.1 din-rail-mounted spring clamp terminal blocks are 4.2 mm wide and accept PTC jumpers that provide for connecting adjoining blocks together or alternating terminal blocks. The wire range is 24-14 AWG, current rating of 17.5 A at 500 V. HMM.1 has all international approvals including cURus. ASI 877/650-5160 www.asi-ez.com
|
 |
Built-In Meter EL3681 and KL3681 terminals integrate digital multimeters directly into I/O nodes and provide precise, simple, high-resistance measurement from 300 mV to 300 V. Measured values can be processed directly in the I/O system or by the master controller. Immunity to interference is achieved by galvanic isolation of the electronic measuring system and a measurement interval of 200 ms. Beckhoff Automation 952/890-0000 www.beckhoffautomation.com
|
 |
Dinnerctor Line DINnector line of terminal blocks includes circuit breaker terminal blocks available in ¼ A to 10 A sizes. Terminal block sockets in 12 V and 24 V come with or without LED indicators, and offer single- and double-level plug-in style. AutomationDirect 770/889-2858 www.automationdirect.com/terminal-blocks
|
| |
I/O Complete 1799-ER DIO board has dual EtherNet/IP ports, redundant wiring and a built-in managed switch. Universal inputs and user-selectable outputs maximize I/O channel use. The board automatically detects an expansion module connection and provides the necessary EDS files embedded within it. Rockwell Automation 414/328-4000 www.ab.com/io/onmachine/1799.html
|
 |
AS-I I/O FAS20 IP20-rated, in-the-cabinet, block I/O stations for AS-interface (AS-i) networks have four inputs or four inputs and four outputs. All ports are terminal blocks in removable and non-removable versions. AS-i bus and AUX power connections can be made via terminal blocks or an optional integrated M12 eurofast bulkhead receptacle for connection outside an enclosure. Turck 800/544-7769 www.turck.us
|
 |
Fail-Safe I/O ET 200M fail-safe modules for Simatic ET 200M I/O station meet requirements of SIL 3/Cat. 4 and PL e in mixed operation with standard modules, without a safety protector. The modules have Profisafe-Profil 2.0 for use in Profinet networks in connection with PN/DP couplers. Modules can send an acknowledgement after a voltage drop and preserve the last valid function, which provides the last valid state, and energize-to-trip functions to provide the last value. Siemens Industry 215/646-7400 www.usa.siemens.com
|
 |
64 Channels Analog input modules for EtherStax provide high-resolution scanning of 64 single-ended channels monitoring dc current or voltage signals. ES2163 and ES2164 models perform 16-bit A/D conversion and interface to Ethernet devices or controllers with Modbus TCP/IP or UDP/IP. Scanning updates all 64 channels in less than 10 ms. ES2163 accepts dc current with ±20, 0-20 or 4-20 mA ranges. ES2164 units accept ±5 or ±10 V. Acromag 248/295-0880 www.acromag.com
|
 |
Combo Block Series 2020 and 2022 X-Com S pluggable connector systems merge touchproof, pre-wired assemblies with TopJob S terminal blocks to combine pluggable connectors, DIN-rail blocks and Cage-Clamp S connection to streamline and eliminate wiring errors during panel and machine building. The terminal blocks are available in single- or double-deck configurations and 3.5 or 5.2 mm pin spacing. Wago 800/din-rail www.wago.us
|
 |
Compact Size Impact20 fieldbus I/O station is designed for applications in terminal boxes and control panels due to its compact size. It is available for CANopen and DeviceNet protocols and as a 16 output only, 16 input only or mixed with eight inputs and eight outputs. Murrelektronik 770/497-9292 www.murrinc.com
|
 |
I/O PLATFORM Advantys STB IP20, bit-modular, distributed I/O platform provides 512 I/O points per island, with up to 32 modules per island on seven segments. Configuration software includes I/O diagnostics, and the platform has hot-swap capability and removable memory cards. Up to 16 I/Os and eight networks can be supported. Schneider Electric 888/778-2733 www.schneider-electric.us
|
 |
Master Distributor microNCS provides Modbus RTU (RS-485) master capabilities, cost-effective distributed data acquisition and, with expansion I/O, control capabilities. One or both of the microNCS's Modbus RTU ports can be configured to poll other RTU slaves with all of the network polling functions of a typical Modbus master. An industry-standard OPC interface delivers plug-and-play integration with popular PC-based HMI and SCADA software packages. Moore Industries 818/894-7111 www.miinet.com
|
 |
Dense-Packed I/O Eurostyle terminal blocks have front-style plugs with a wire-entry cavity and activating screw head located on the same plane, parallel to the direction of the plug, which allows the plugs to be densely stacked, side by side. Offered in 5.0 and 5.08 mm centerline spacings, the blocks have a current rating of 300 V and 16 A, are available with 2-12 positions, and accommodate 14-24 AWG wires. Tyco Electronics 717/986-5326 www.tycoelectronics.com
|
 |
Analog I/O Backpanels Analog I/O signal channels provide each 8B module with an analog bus, and all module outputs are simultaneously accessible to high-speed data acquisition boards. A temperature sensor provides cold junction compensation for thermocouple input modules. It has a -40 to 85 °C operating range, and high-density screw clamp, 16 AWG max, interface connector. Dataforth 800/444-7644 www.dataforth.com
|
 |
Can Two CANopen extension module 1 SI for Simatic ET200S I/O system connects CAN 2.0A and CANopen devices with the integration of the CAN 2.0A protocol. The module can be used for transmission/reception of any CAN 2.0A frame regardless of the overlaying CAN application protocol. The module can be engineered with Step7, and allows upgrading already-existing 1 SI CANopen boards with this new functionality. HMS Industrial Networks 312/829-0601 www.hms-networks.com
|
 |
PAC INPUTS 125 Vdc input module for the RX3i controller provides 16 input points in one group with a common power input terminal, one control engine, 300 MHz Intel microprocessor and 10 MB of user memory, a universal backplane with a high-speed PCI bus and a serial bus for simple I/O. GE Intelligent Platforms 800/433-2682 www.ge-ip.com/pac
|
 |
Measurement Module Snap-AIPM-3 analog input module measures and manages three-phase ac power usage, mounts on an I/O rack and measures Vac rms and Aac rms. The module calculates true power, Volt-Amps and power sums for all three phases of power. When used with Snap controllers or I/O, it can support controlling and regulating equipment and facility power monitoring. Opto 22 951/695-3000 www.opto22.com
|