Home » HART Recognizes Mitsubishi Chemical
HART Recognizes Mitsubishi Chemical
IndustrialNetworking.net
02/04/2010
The HART Communication Foundation (www.hartcomm.org) selected the Mitsubishi Chemical ethylene plant located in Kashima, Japan, as recipient of the 2009 HART Plant of the Year Award. The award is given annually to recognize the people, companies and plant sites around the globe that use the advanced capabilities of HART Communication in real-time applications to improve operations, lower costs and increase availability. Mitsubishi is Japan’s largest chemical manufacturer.
Mitsubishi Chemical uses the HART capability of more than 800 interoperable field devices integrated with its DCS and asset management systems through multiplexers and HART-enabled I/Os to access real-time, continuous process variables and diagnostics. By accessing this real-time intelligent data, Mitsubishi can diagnose abnormal process conditions and track equipment health 24 hrs/day. As a result, peak production performance improved with an estimated operational savings for the plant of $20000-$30000 per day.
Diagnostics also are used to uncover device failures before they affect the process. It is estimated that two or three device failures have been detected that would otherwise have caused unplanned shutdowns. An unscheduled plant shutdown costs an estimated $600,000 in lost production value per day with a minimum production restart time of five days for a total savings of around $3 million.
"Diagnostic parameters that help detect signs of an abnormal situation or degrading performance are difficult to obtain with simple handheld devices because they require a time-consuming, manual, step-by-step approach," says Takayuki Aoyama, team leader, instrumentation group, Mitsubishi Chemical. "HART technology made it possible to access this data without manual operation. This made it much easier for us to gather data and detect abnormal situations from field devices and reduced maintenance costs by 10%."
In addition, trending and analysis of secondary process variables throughout the plant provide process insight that allows plant engineers to analyze, troubleshoot and resolve a number of operational problems including plugged impulse lines, an unstable flow profile and an inefficient compressor pump.

HART Communication Foundation Director of Technology Programs Ed Ladd
(left to right) and Executive Director Ron Helson present the 2009 HART
Plant of the Year Award to Mitsubishi Chemical’s Takayuki Aoyama, team leader,
maintenance and engineering, instrumentation group; Kenji Tsutsui, general
manager, maintenance and engineering; and Nobuyuki Mishima, group manager,
maintenance and engineering, instrumentation group, in Kashima, Japan.
HART COMMUNICATION FOUNDATION
"We designated HART as our standard communication protocol, and will replace older devices with HART-type whenever we get a chance," says Takayuki. "We use HART communication to collect online data from our field devices without disturbing the 4-20 mA analog signal to the control system. Our goal is to detect abnormal situations in the process and protect field devices from malfunctions."
Mitsubishi Chemical is a perfect example of how the power of HART can be used to lower costs, improve plant availability and help keep a plant competitive, says Ron Helson, HART Communication Foundation’s executive director.
Mitsubishi Chemical, including subsidiaries, has 39000 employees. The ethylene plant capacity is 380000 tons/year. Approximately 800 HART devices are currently installed in the plant with an additional 2200 4-20 mA only devices that will be upgraded over time.
The HART Plant of the Year is presented to end-user companies to recognize ingenuity in the application of HART Communication technology. The award showcases end-user companies and their suppliers who have demonstrated creativity in using the full capabilities of HART Communication technology.
More News:
-
02/08/2012
PLCopen, OPC Foundation Connect on MES
PLCopen and OPC Foundation have begun to cooperate on manufacturing execution system (MES) connectivity, integrating machine and process data for MES use based on OPC UA and PLCopen standards.
-
02/08/2012
Wireless Sensor Networks Expand
The wireless sensor network (WSN) market is poised to grow rapidly in the coming years
-
02/08/2012
ODVA Recommends Cybersecurity Guidelines
Interconnectivity between plant floor and enterprise systems can boost productivity, it can introduce security risks
-
02/03/2012
PLCopen Extends Motion Control Spec
The Suite of PLCopen Motion Control Specifications Has Been Extended With the Release of Part 5 and Part 6
-
02/03/2012
PLCs Make Speedy Recovery
Global Revenues From PLCs Were nearly 30 Percent Higher in 2010 Than They Were in 2009, Reaching More Than $8 Billion. IMS Research Says That the PLC Market Will Continue to Grow in 2012
-
02/03/2012
15 Years of Control Design: Flashback 1997-2012 - February
February Highlights Included Several Advances in Both Space and Cyberspace
-
01/31/2012
Mechatrolink Offers Free Membership Upgrade
Until the End of March, Mechatrolink Members Assn. Is Offering a Year’s Regular Membership, Which Normally Costs $1,500, for Free
-
01/30/2012
ABB to Acquire Thomas & Betts
ABB Will Pay $3.9 Billion to Become a Major Player in the North American Low-Voltage Products Market. The Transaction, Subject to Approvals, Should Close by Mid-Year.
-
01/24/2012
Shell Canada Site Receives 2011 HART Plant of the Year Award
Shell’s Scotford Upgrader Facility Won This Year’s Award for Using HART Communication to Expand Capacity Safely and Efficiently
-
01/23/2012
Participate in Our 2012 Machine Buying Habits Survey
We Want to Learn About the Methods You Prefer to Use When You Do Your Automation and Control Products Research
- All news »
Sponsored Links
Control Design Digital Edition
Access the entire print issue on-line and be notified each month via e-mail when your new issue is ready for you. Subscribe today.
- Featured White Papers

Print page